Compaq HSG80 - StorageWorks RAID Array Controller Dokumentacja Strona 279

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 396
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 278
7–83
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
RETRY_ERRORS UNWRITEABLE_DATA
Causes the controller to attempt to write previously unwriteable data from the write-
back cache to the devices. If a container fails, preventing the data in write-back cache
to be written to the container, an unwriteable data error is reported. If possible, correct
the condition that caused the unwriteable data and try the write operation again. No
data is lost if the retry fails.
Syntax
RETRY_ERRORS unit-number UNWRITEABLE_DATA
Parameter
unit-number
Identifies the unit number to which the data contained in write-back cache tries to
write. The unit-number is the same name given to the unit when it was created using
the ADD UNIT command.
Example
This example shows how to retry writing the cached data previously marked
unwriteable to disk unit D103:
RETRY_ERRORS D103 UNWRITEABLE_DATA
See also
CLEAR_ERRORS unit-number UNWRITEABLE_DATA
Przeglądanie stron 278
1 2 ... 274 275 276 277 278 279 280 281 282 283 284 ... 395 396

Komentarze do niniejszej Instrukcji

Brak uwag