Configuring Storagesets
Use the following procedure to move a storageset while maintaining the data it
contains:
1. Show the details for the storageset you want to move. Use the following
command:
SHOW
storageset-name
2. Label each member with its name and PTL location.
If you do not have a storageset map for your subsystem, you can enter the
LOCATE command for each member to find its PTL location. Use the following
command:
LOCATE
disk-name
To cancel the locate command, enter the following:
LOCATE CANCEL
3. Delete the unit-number shown in the “Used by” column of the SHOW storageset-
name command. Use the following command:
DELETE
unit-number
4. Delete the storageset shown in theName” column of the SHOW storageset-
name command. Use the following command:
DELETE
storageset-name
5. Delete each disk drive—one at a timethat the storageset contained. Use the
following command:
DELETE
disk-name
DELETE
disk-name
DELETE
disk-name
6. Remove the disk drives and move them to their new PTL locations.