CLI Commands
POWEROFF
Powers off all disk units in a cabinet and turns off the cabinet power.
Syntax
POWEROFF
Switches
BATTERY _ON
BATTERY_OFF (Default)
Instructs the external cache battery (ECB) charger to turn off or remain on.
Specify BATTERY_ON to keep the ECB charger on after the POWEROFF command
is issued.
Specify BATTERY_OFF to turn off the ECB charger after the POWEROFF command
is issued.
NOTE: The ECB LEDs will continue to flash in both cases, but the cache module
LEDs cease flashing when BATTERY_OFF is chosen.
OVERRIDE_BAD_FLUSH
NO_OVERRIDE_BAD_FLUSH (Default)
Instructs the controller to either poweroff the cabinet or remain on depending on the
cache flush results.
Specify OVERRIDE_BAD_FLUSH to override a failed cache flush and poweroff the
cabinet.
Specify NO_OVERRIDE_BAD_FLUSH to prevent a poweroff when the cache flush
fails.