Compaq HSG80 - StorageWorks RAID Array Controller Dokumentacja Strona 221

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 396
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 220
7–25
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Examples
To create a stripeset named STRIPE1 with three disks: DISK10000, DISK20100, and
DISK30200, enter:
ADD DISK DISK10000 1 0 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30200 3 2 0
ADD STRIPESET STRIPE1 DISK10000 DISK20100 DISK30200
To create a stripeset named STRIPE1 and then create a logical unit from it, type:
INITIALIZE STRIPE1
ADD UNIT D103 STRIPE1
This example shows how to create a two-member striped mirrorset (a stripeset whose
members are mirrorsets), and how to create a logical unit from it. Because you can
initialize the stripeset, you do not need to individually initialize the mirrorsets.
ADD DISK DISK10000 1 0 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30200 3 2 0
ADD DISK DISK40300 4 3 0
ADD MIRRORSET MR1 DISK10000 DISK20100
ADD MIRRORSET MR2 DISK30200 DISK40300
ADD STRIPESET STRIPE1 MR1 MR2
INITIALIZE STRIPE1
ADD UNIT D104 STRIPE1
Przeglądanie stron 220
1 2 ... 216 217 218 219 220 221 222 223 224 225 226 ... 395 396

Komentarze do niniejszej Instrukcji

Brak uwag