Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Destroy/Nodestroy
Specify whether to destroy or retain the user data and metadata when you initialize a
disk drive that has been previously used in a mirrorset or as a single-disk unit.
NOTE: The DESTROY and NODESTROY switches are only valid for striped
mirrorsets and mirrorsets.
DESTROY (default) overwrites the user data and forced-error metadata on a disk
drive when it is initialized.
NODESTROY preserves the user data and forced-error metadata when a disk
drive is initialized. Use NODESTROY to create a single-disk unit from any disk
drive that has been used as a member of a mirrorset. The NODESTROY switch is
not valid for RAIDsets and single-disk configurations.
See “REDUCE,” page 7–77 for information on removing disk drives from a
mirrorset.
See “INITIALIZE,” page 7–62 for more information on saving the configuration.