Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
RESTART
controller
Flushes all user data from the specified controller’s write-back cache and restarts the
controller.
Syntax
RESTART controller
Parameters
controller
The controller parameter indicates which controller is to be restarted. Specify
OTHER_CONTROLLER or THIS_CONTROLLER.
Switches
IGNORE_ERRORS
NOIGNORE_ERRORS (Default)
Controls the reaction of the controller based on the status of write-back cache.
CAUTION: The IGNORE_ERRORS switch might cause the controller to
keep unflushed data in the write-back cache until it restarts and is able
to write the data to devices. Do not perform any hardware changes until
the controller flushes the cache.
Specify IGNORE_ERRORS to instruct the controller to restart even if the data within
write-back cache cannot be written to the devices.
Specify NOIGNORE_ERRORS to instruct the controller to not restart if the data
within write-back cache cannot be written to the devices.