Przeglądanie stron 1
COMPAQ StorageWorks Upgrading From an HSZ70 to an HSG80 Array Controller
Page 2 EK-HSG80-UP. B01
If after reading this guide, you determine that you want assistance with upgrading your RAID
system, please contact a Compaq Services representative.
NOTE
The HSZ70 Array Controller uses a trilink connector with SCSI
host bus cables. The HSG80 Array Controller uses fibre optic
host cables. The following procedures assume that the user
has the appropriate fibre channel cables and hubs to connect
to the host subsystem.
CAUTION
The HSG80 controller(s) that will be used in this procedure
must be factory default. If the controller(s) have been used or
the packages have already been opened, they must be
restored to the factory default state before starting the
upgrade process. The procedure described in Appendix B can
be used to restore the factory default configuration; however,
that procedure could also erase customer and configuration
data; therefore, it should NOT be used on a RAID subsystem
containing data.
1.0 Upgrade Restrictions
Before starting the upgrade procedure review this entire document and the following criterion to
determine if this upgrade will meet your requirements.
Upgrades Supported:
HSZ70 Version 7.1 to HSG80 Version 8.3 on:
Windows NT
HP-UX
SGI IRIX
SUN Solaris
Digital Unix/Tru64 Unix
IBM AIX
StorageWorks Command Console Version 2.0 to Version 2.1.
Table 1-1 compares the maximum number of HSZ70 SCSI Logical Units versus the maximum
number of HSG80 Fibre Channel units supported by the various operating systems. If your
server operating system supports fewer Fibre Channel Logical Units than SCSI Logical Units,
the system administrator will need to consolidate some Logical Units.
Table 1–1 Number of HSZ70 SCSI Logical Units vs. HSG80 Fibre Channel Logical Units
Connection Type
Operating System
SCSI Logical Units
Fibre Channel Logical Units
SUN Solaris 8 TIDs X 8 LUNs = 64 LUNs 2 ALPAs X 64 LUNs = 128 LUNs
HP UNIX 8 TIDs X 8 LUNs = 64 LUNs 2 ALPAs X 8 LUNs =16 LUNs
SGI IRIX 8 TIDs X 8 LUNs = 64 LUNs 2 ALPAs X 64 LUNs = 128 LUNs
Przeglądanie stron 1
1 2 3 4 5 6 7 ... 27 28