COMPAQ StorageWorks Upgrading From an HSZ70 to an HSG80 Array Controller
Page 14 EK-HSG80-UP. B01
For Fibre Channel switch environments the topology using:
HSG80> SET THIS_CONTROLLER PORT_1_TOPOLOGY=FABRIC
HSG80> SET THIS_CONTROLLER PORT_2_TOPOLOGY=FABRIC
Using information from the Installation Reference Guide for your server’s operating system,
set the Arbitrated Loop Physical Address (ALPA) NN of the controller ports using:
HSG80> SET THIS_CONTROLLER PORT_1_AL_PA=NN
HSG80> SET THIS_CONTROLLER PORT_2_AL_PA= NN
Set the SCSI version using:
HSG80> SET THIS_CONTROLLER SCSI_VERSION=SCSI-2
Restart this controller for the new settings to take effect.
HSG80> RESTART THIS_CONTROLLER
If the configuration being upgraded is a single controller proceed to Section 11.0, Creating
the HSG80 Logical Units. If the configuration included dual-redundant controllers, install the
second controller as outlined in the next section.