Compaq AlphaServer ES40 Informacje Techniczne Strona 182

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 181
5-20 Compaq AlphaServer ES40 Service Guide
5.5
Windows NT Error Logs
The Display Error Frames selection of the AlphaBIOS Utilities menu
allows you to view hardware error reports for systems running
Windows NT. A report is generated if a fatal error or double error halt
occurs. If the System Error Logging Software for Alpha kit is installed,
you will be able to see the report in the system event log after the
system has booted.
Figure 5–6 New Error Frame Was Detected Window
PK0955
AlphaServer
AlphaBIOS 5.68
Alpha Processor and System Information:
New Error Frame was detected
AlphaBIOS has detected a new hardware error report in the
error frame sector of the flash ROM in this system. If
the Alpha hardware error logging service is installed,
then you will be able to see this report in the system
event log after the system is booted.
This report frame can also be examined from AlphaBIOS:
Press F2 to enter the main AlphaBIOS Setup screen, then
select Utilities, and then select Display Error Frames.
This window will be closed in 25 sec.
0568
1.2d
S
M
SPACE =Confirm ESC=Stop Count Down
The next time you boot the system after a fatal error or double error halt,
AlphaBIOS displays the message shown in Figure 5–6 just after initialization
has been completed and just before the Boot menu is displayed. The message is
closed after 30 seconds. To keep the message window open, press the ESC key
before the count down time has elapsed.