Compaq AlphaServer ES40 Informacje Techniczne Strona 112

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 111
4-8 Compaq AlphaServer ES40 Service Guide
4.3
cat el and more el
The cat el and more el commands display the contents of the console
event log.
In Example 4–2, the console reports that CPU 1 did not power up and fans 1
and 2 failed.
Example 4–2 more el
>>> more el
*** Error - CPU 1 failed powerup diagnostics ***
Secondary start error
EV6 BIST = 1
STR status = 1
CSC status = 1
PChip0 status = 1
PChip1 status = 1
DIMx status = 0
TIG Bus status = 1
DPR status = 0
CPU speed status = 0
CPU speed = 0
Powerup time = 00-00-00 00:00:00
CPU SROM sync = 0
*** Error - Fan 1 failed ***
*** Error - Fan 2 failed ***
Przeglądanie stron 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 443 444

Komentarze do niniejszej Instrukcji

Brak uwag