SRM Console Diagnostics 4-51
Table 4–3 lists bit assignments for failures that could potentially be listed in the
E (error) field of the show fru command. Because the E field is only two
characters wide, bits are “or’ed” together if the device has multiple errors. For
example, the E field for a FRU with both TDD (02) and SDD (04) errors would
be 06:
010 | 100 = 110 (6)
Table 4–3 Bit Assignments for Error Field
Bit Mask
(E Field) Meaning
01 Hardware failure
02 TDD error has been logged
04 SDD error has been logged
08 Reserved
10 Checksum failure on bytes 0-62
20 Checksum failure on bytes 64-126
40 Checksum failure on bytes 128-254
80 FRU’s system serial number does not match system’s