8.2.1 Booting the LFU from the Infoserver system disk
Once the LFU image is on the Infoserver system disk (see Section 8.2), it is booted as follows.
This is slightly different to booting from the console CD in that the Initial System Loader
is not used. Because the image was "mop enabled" it can be loaded directly:
>>> boot -flags 0,0,0 exa0 -file VAX7000_Vnn ; for VAX systems (nn = version)
>>> boot -flags 0,0,0 exa0 -file AXP7000_Vnn ; for AXP systems (nn = version)
You don’t get the menu of services (as per ISL_VAX etc.), The LFU banner and menu appear
directly.
9 RDC
Figure 5 shows how to connect a 7000/10000 system to RDC. The MDS01 baud rates should
be set to 9600 for the console line (T switches) and 1200 for the modem line (M switches).
See Datadoc - VAX 6000 section, for more information on MDS01 and modem setup.
Figure 5: Connecting to RDC
BC22F*
$ MDS01 A1 B1
(rear view)
* BC22F can be replaced with H8575−A BC22F
a BC16−E and H8571−D
MODEM
Console
(MMJ)
17−01364−02
A2 B2
VAX/DEC 7000/10000
RDC