Przeglądanie stron 49
Infortrend
2-11
Date and time
N/A
Time zone
+ 8 hrs
Optimization Mode:
Write-back Cache
Enabled Disabled
Array stripe size
Related to controller general
setting
4KB to 256KB
Optimization for
Random/Sequential
Sequential Either (sequential for LD larger than
512MB and can not be changed)
Array write policy
Related to controller general
setting
W/B or W/T
SCSI Parameters:
Data Transfer Rate
* Async. To 100.0MHz
Maximum Tag Count
32 1-128
Maximum Queued
I/O Count
32 32 to 1024
LUN’s per SCSI ID
8Up to 32
Periodic Drive Check
Time
Disabled Enabled
Periodic SAF-TE and
SES Device Check
Time
5 Disabled to 60 seconds
Periodic Auto-Detect
Failure Drive Swap
Check Time
Disabled 5 to 60 seconds
Number of Host-LUN
Connection
32 1 to 1024
Tag per Host-LUN
Connection
32 1 to 256
Wide Transfer
* Enabled/Disabled
Parity Check
Disabled Enabled
Spin-Up Parameters:
Motor Spin-Up
Disabled Enabled
Reset at Power-UP
Enabled Disabled
Initial Disk Access
Delay
* None to 75 seconds
Fibre Channel Parameters:
Fibre Connection
Options
* Loop Only
Point-to-Point Only
Loop Preferred
Point-to-Point Preferred
Fibre Channel Dual-
Loop
Enabled Enabled by cabling
Host ID/WWN name
list
* User configurable
LUN Filtering
* Host Access Filter Control
Configurable - filter type - access
right - name
RCC through Fibre
channel
* Dedicated or sharing drive channel(s)
Przeglądanie stron 49