Przeglądanie stron 272
Infortrend
12-14
Follow the steps described in the previous section to "add" or "copy
& replace" SCSI disk drives and perform Logical Drive Expansion.
The 16.5GB logical drive has become a 25GB logical drive. Place the
cursor on that logical drive, and then press [ENTER].
From the menu, select "Partition Logical Drive." You will see that
the 25GB logical drive is composed of a 17GB partition and an 8.4GB
partition.
Follow the directions in chapter 5 and chapter 7 to map the new
partition to a Host LUN. The new partition must be "mapped" to a
host LUN in order for the HBA (host-bus adapter) to see it. Once
you have mapped the partition, reboot your Windows server. The
HBA should be able to detect an additional “disk” during the
initialization process.