Table 2–2: RAID Controller Minimum Required Array Controller Software
RAID Controller
Minimum Required Array Controller
Software
HSZ20
3.4
HSZ22 (RAID Array 3000) D11x
HSZ40
3.7
HSZ50
5.7
HSZ70
7.7
HSZ80
8.3-1
HSG60
8.5
HSG80
8.5
RAID controllers can be configured with the number of SCSI IDs as listed
in Table 2–3.
Table 2–3: RAID Controller SCSI IDs
RAID Controller Number of SCSI IDs Supported
HSZ20
4
HSZ22 (RAID Array 3000)
2
HSZ40
4
HSZ50
4
HSZ70
8
HSZ80
15
HSG60 N/A
HSG80 N/A
The following restrictions are imposed for support of the StorageWorks RAID
Array 3000 (RA3000) subsystem:
The RAID Array 3000 (RA3000) with HSZ22 controller does not
support multi-bus access or multiple-bus failover. You cannot achieve a
no-single-point-of-failure (NSPOF) cluster using an RA3000.
The KZPBA-CB UltraSCSI host adapter is the only SCSI bus host
adapter supported with the RA3000 in a TruCluster Server cluster. The
KZPBA-CB requires ISP 1020/1040 firmware Version 5.57 (or higher),
which is available with the system SRM console firmware on the Alpha
Systems Firmware 5.4 or later Update CD.
Hardware Requirements and Restrictions 2–11