Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Instrukcja Obsługi Strona 258

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 422
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 257
Table 8–1: TZ88N-VA Switch Settings (cont.)
SCSI ID SCSI ID Selection Switches
6
Off On On Off Off Off
7
On On On Off Off Off
a
SBB tape drive SCSI ID is determined by the SBB physical slot.
8.1.2 Cabling the TZ88N-VA
There are no special cabling restrictions specific to the TZ88N-VA; it is
installed in a BA350 StorageWorks enclosure. A DWZZA-VA installed in slot
0 of the BA350 provides the connection to the shared SCSI bus. The tape
drive takes up three slots.
You must remove the DWZZA-VA differential terminators. Ensure that
DWZZA-VA jumper J2 is installed to enable the single-ended termination.
The BA350 jumper and terminator must be installed.
A trilink connector on the DWZZA-VA differential end allows connection to
the shared bus. An H879-AA terminator is installed on the trilink for the
BA350 on the end of the bus to provide shared SCSI bus termination.
8–4 Configuring a Shared SCSI Bus for Tape Drive Use
Przeglądanie stron 257
1 2 ... 253 254 255 256 257 258 259 260 261 262 263 ... 421 422

Komentarze do niniejszej Instrukcji

Brak uwag