Compaq 4354R - StorageWorks Enclosure Storage Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Macierze dyskowe Compaq 4354R - StorageWorks Enclosure Storage. Compaq 4354R - StorageWorks Enclosure Storage Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 218
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Compaq StorageWorks

Compaq StorageWorksFirst Edition (June 2001)Part Number: AA-RFAUD-TECompaq Computer CorporationHSG80 ACS Solution Software Version 8.6 for Compaq Tru6

Strona 3 - Contents

3–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFor V4.0G# mount /dev/rza8c /mntFor V5.1x# mount

Strona 4 - Chapter 2

Preparing the Host System 3–9HSG80 Units and Tru64 UNIX Utilities This section contains notes on the interactions of some Tru64 UNIX utilities with st

Strona 5 - Chapter 3

3–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideThe device activity indicator (green light) wil

Strona 6

Preparing the Host System 3–11scu You can use the SCSI CAM Utility (scu) program to see which HSG80 units are available to the Tru64 UNIX Operating Sy

Strona 7

3–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideHSG80 units appear like any other SCSI device.

Strona 8

Preparing the Host System 3–13The above display shows activity on all 8 LUNs attached to one SCSI-bus (2), one Target 0. The above list represents inf

Strona 10

Chapter 4Installing and Configuring the HS-Series AgentThe following information is included in this chapter: “Why Use StorageWorks Command Console (

Strona 11

4–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideThe Agent can also be used as a standalone appli

Strona 12

Installing and Configuring the HS-Series Agent 4–3Installation and Configuration OverviewTable 4–2 provides an overview of the installation.Table 4–2

Strona 13

FiguresFigure 1 General configuration flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxFigure 2 C

Strona 14

4–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 4–1. An example of a network connection1

Strona 15 - About this Guide

Installing and Configuring the HS-Series Agent 4–5Before Installing the Agent1. Log in as root (superuser). Agent installations on Tru64 UNIX must be

Strona 16 - Text Conventions

4–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide4. Change directories on the CD-ROM by entering:

Strona 17 - Symbols on Equipment

Installing and Configuring the HS-Series Agent 4–710. Press press the Enter key. A menu for selecting a client system notification scheme appears:11.

Strona 18 - Rack Stability

4–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide17. Enter the subsystem name in lowercase letter

Strona 19 - Configuration Flowchart

Installing and Configuring the HS-Series Agent 4–9Final System Configuration26. Do one of the following:❏ If you are running the Agent in cluster, sel

Strona 20

4–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide4. Change directories on the CD-ROM by entering

Strona 21 - About this Guide xxi

Installing and Configuring the HS-Series Agent 4–1110. Press press the Enter key. A menu for selecting a client system notification scheme appears:11.

Strona 22 - Compaq Technical Support

4–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide17. Enter the subsystem name in lowercase lette

Strona 23 - Compaq Authorized Reseller

Installing and Configuring the HS-Series Agent 4–13Final System Configuration26. Do one of the following:❏ If you are running the Agent in cluster, se

Strona 24

xii HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 2–11 A 3-member RAID 0 stripeset (example

Strona 25 - Planning a Subsystem

4–14 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideCAUTION: After you make a change to the config

Strona 26 - Defining the Subsystems

Installing and Configuring the HS-Series Agent 4–15Removing the Agent1. Enter the following and press the Enter key:# setld -d SWCC510The procedure t

Strona 27 - Controller”

4–16 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide2. Do one of the following:❏ Select option y an

Strona 28 - Model 2200 Enclosure

Chapter 5Configuration ProceduresThis chapter describes procedures to configure a subsystem that uses Fibre Channel fabric topology. In fabric topolog

Strona 29 - Selecting a Failover Mode

5–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideIMPORTANT: These configuration procedures assum

Strona 30 - —normal operation

Configuration Procedures 5–3CAUTION: The maintenance port generates, uses, and can radiate radio-frequency energy through its cables. This energy may

Strona 31 - Multiple-Bus Failover Mode

5–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 5–2. Single controller cablingConfigurin

Strona 32

Configuration Procedures 5–5See “Worldwide Names (Node IDs and Port IDs),” page 1–28, for the location of the sticker.The node ID is located in the th

Strona 33 - Selecting a Cache Mode

5–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideNOTE: Setting the SCSI version to SCSI-3 does n

Strona 34 - Write-Through Caching

Configuration Procedures 5–7When FRUTIL asks if you intend to replace the battery, answer “Y”:Do you intend to replace this controller's cache ba

Strona 35 - The Command Console LUN

TablesTable 1–1 Unit Assignments and SCSI_VERSION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–21Table 2–1 A Comparison of Container

Strona 36 - Disabling the CCL

5–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide13. Turn on the switches, if not done previously

Strona 37

Configuration Procedures 5–9Setting Up a Controller PairPower Up and Establish Communication1. Connect the computer or terminal to the controller as s

Strona 38 - D100 D101 D120D0 D1

5–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideThe following figure shows a controller pair wi

Strona 39 - Planning a Subsystem 1–15

Configuration Procedures 5–11The node ID is located in the third line of the SHOW THIS result:HSG80> show thisController: HSG80 ZG80900583 Softwa

Strona 40 - Assigning Unit Numbers

5–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide6. Set the topology for the controller. If both

Strona 41 - 0). Unit D102 will

Configuration Procedures 5–1312. Verify node ID, allocation class, SCSI version, failover mode, identifier, and port topology. The following display i

Strona 42 - CXO6455B

5–14 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideThe first connection will have one or more entr

Strona 43 - Failover Mode

Configuration Procedures 5–15Configuring DevicesThe disks on the device bus of the HSG80 can be configured manually or with the CONFIG utility. The CO

Strona 44 - SCSI-2 Mode

5–16 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideNOTE: See the ADD MIRRORSET command in the Com

Strona 45

Configuration Procedures 5–174. Assign the RAIDset a unit number to make it accessible by the hosts. See “Assigning Unit Numbers and Unit Qualifiers”

Strona 47

5–18 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideConfiguring a Single-Disk Unit (JBOD)1. Initial

Strona 48

Configuration Procedures 5–19The partition number appears in the first column, followed by the size and starting block of each partition.4. Assign the

Strona 49 - Planning a Subsystem 1–25

5–20 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideAssigning a Unit Number to a Single (JBOD) Disk

Strona 50

Configuration Procedures 5–21Configuration OptionsChanging the CLI PromptTo change the CLI prompt, enter a 1- to 16- character string as the new promp

Strona 51

5–22 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideNOTE: This procedure assumes that the disks th

Strona 52

Configuration Procedures 5–23To disable autospare, use the following command:SET FAILEDSET NOAUTOSPAREDuring initialization, AUTOSPARE checks to see i

Strona 53 - Planning a Subsystem 1–29

5–24 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideChanging RAIDset and Mirrorset SwitchesUse the

Strona 54 - SHOW command to list the LUN

Chapter 6Verifying Storage Configuration from the HostThis chapter briefly describes how to verify that multiple paths exist to virtual disk units und

Strona 55 - Planning Storage

6–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide130: /dev/disk/dsk63c DEC HSG80 bus-5-targ-10-lu

Strona 56 - Where to Start

Chapter 7Configuration Example Using CLIThis chapter presents an example of how to configure a storage subsystem using the Command Line Interpreter (C

Strona 57 - Configuration Rules

About this GuideThis guide provides installation and configuration instructions and reference material for operation of the HSG80 ACS Solution Softwar

Strona 58 - CXO5851B

7–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 7–1 shows an example storage system map f

Strona 59

Configuration Example Using CLI 7–3.Figure 7–2. Example systemThe following figure represents units that are logical or virtual disks comprised of st

Strona 60

7–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 7–3. Example virtual system layout from

Strona 61 - Planning Storage 2–7

Configuration Example Using CLI 7–5RESTART THISSET THIS TIME=10-Mar-2001:12:30:34RUN FRUTILYPlug serial cable from maintenance terminal into bottom co

Strona 62

7–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideMark or tag both ends of Fibre Channel cables.Pl

Strona 63 - Planning Storage 2–9

Configuration Example Using CLI 7–7Mark or tag both ends of Fibre Channel cablesRepeat this process to add connections from the other two hosts. The r

Strona 64 - CXO6186B

7–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideRUN CONFIGADD RAIDSET R1 DISK10000 DISK20000 DIS

Strona 65 - Choosing a Container Type

Configuration Example Using CLI 7–9ADD UNIT D2 S2 DISABLE_ACCESS_PATH=ALLSET D2 ENABLE_ACCESS_PATH=(GREY1A1, GREY1B1, GREY2A2, GREY2B2)INITIALIZE DISK

Strona 67 - Planning Storage 2–13

Chapter 8Backing Up the Subsystem, Cloning Data forBackup, and Moving StoragesetsThis chapter describes some common procedures that are not mentioned

Strona 68 - CXO7287A

xvi HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideText ConventionsThis document uses the following

Strona 69 - CXO4592B

8–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideCloning Data for BackupUse the CLONE utility to

Strona 70

Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets 8–3Figure 8–1. Steps the CLONE utility follows for duplicating unit members

Strona 71 - C'C

8–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideThe following example shows the commands you wou

Strona 72 - Operating

Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets 8–5USE AVAILABLE DEVICE DISK20300(SIZE=832317) FOR MEMBER DISK10000(SIZE=832

Strona 73

8–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideMoving StoragesetsYou can move a storageset from

Strona 74 - CXO7289A

Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets 8–75. Delete each disk drive, one at a time, that the storageset contained.

Strona 76 - Defining a Partition

Appendix ASubsystem Profile TemplatesThis appendix contains storageset profiles to copy and use to create your system profiles. It also contains an en

Strona 77 - Switches

A–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStorageset ProfileStorageset Name Disk DrivesUni

Strona 78 - RAIDset Switches

Subsystem Profile Templates A–3Storage Map Template 1 for the BA370 EnclosureUse this template for: BA370 single-enclosure subsystems first enclosur

Strona 79 - Initialization Switches

About this Guide xviiSymbols in TextThe symbols found in this guide have the following meanings:WARNING: Text set off in this manner indicates that f

Strona 80 - Chunk Size

A–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStorage Map Template 2 for the second BA370 Encl

Strona 81

Subsystem Profile Templates A–5Storage Map Template 3 for the third BA370 EnclosureUse this template for the third enclosure of multiple BA370 enclosu

Strona 82 - Geometry

A–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStorage Map Template 4 for the Model 4214R Disk

Strona 83 - Storage Maps

Subsystem Profile Templates A–7Storage Map Template 5 for the Model 4254 Disk EnclosureUse this template for a subsystem with a three-shelf Model 4254

Strona 84

A–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidecontinued from previous pageModel 4254 Disk Encl

Strona 85 - − example storage map

Subsystem Profile Templates A–9Storage Map Template 6 for the Model 4310R Disk EnclosureUse this template for a subsystem with a six-shelf Model 4310R

Strona 86

A–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidecontinued from previous pageModel 4310R Disk En

Strona 87 - − example storage map

Subsystem Profile Templates A–11Storage Map Template 7 for the Model 4350R Disk EnclosureUse this template for a subsystem with a three-shelf Model 43

Strona 88

A–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStorage Map Template 8 for the Model 4314R Disk

Strona 89 - Planning Storage 2–35

Subsystem Profile Templates A–13continued from previous pageModel 4314R Disk Enclosure Shelf 1 (single-bus)Bay1234567891011121314SCSI ID 00 01 02 03 0

Strona 90

xviii HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuidePower Supplies or Systems marked with these sy

Strona 91 - Planning Storage 2–37

A–14 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStorage Map Template 9 for the Model 4354R Disk

Strona 92

Appendix BInstalling, Configuring, and Removing the ClientThe following information is included in this appendix: “Why Install the Client?,” page B–1

Strona 93 - Preparing the Host System

B–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideBefore You Install the Client1. Verify you are l

Strona 94

Installing, Configuring, and Removing the Client B–33. Select HSG80 Controller and click Next. NOTE: If the computer does not find a previous install

Strona 95 - Preparing the Host System 3–3

B–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideIf the Network Information Services (NIS) are be

Strona 96 - CXO7382A

Installing, Configuring, and Removing the Client B–5Adding the Storage Subsystem and its Host to the Navigation TreeThe Navigation Tree enables you to

Strona 97 - Making a Physical Connection

B–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure B–2. Navigation window showing storage h

Strona 98 - FileSystem

Installing, Configuring, and Removing the Client B–7Removing the Command Console ClientBefore you remove the Command Console Client (CCL) from the com

Strona 99 - Mounting the Filesystem

B–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideWhere to Find Additional InformationYou can find

Strona 100 - Using genvmunix

GlossaryThis glossary defines terms pertaining to the ACS solution software. It is not a comprehensive glossary of computer terms.adapter A device tha

Strona 101 - File Utility

About this Guide xixConfiguration FlowchartA three-part flowchart is shown on the following pages. Refer to these charts while configuring a new stora

Strona 102 - Reading from the device, dd

Glossary–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidebad block replacementAbbreviated BBR. A r

Strona 103 - V5.1x Output

Glossary–3coax A two-conductor wire in which one conductor completely wraps the other with the two separated by insulation.cold swap A method of devic

Strona 104 - For V4.0G

Glossary–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidedata striping The process of segmenting l

Strona 105 - For V5.1x

Glossary–5EIA The abbreviation for Electronic Industries Association. EIA is a standards organization specializing in the electrical and functional ch

Strona 106

Glossary–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFC–PH The Fibre Channel Physical and Sign

Strona 107 - Chapter 4

Glossary–7FMU Fault management utility. forced errors A data bit indicating a corresponding logical data block contains unrecoverable data.frame An in

Strona 108

Glossary–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidehost adapter A device that connects a hos

Strona 109

Glossary–9I/O Refers to input and output functions.I/O driver The set of code in the kernel that handles the physical I/O to a device. This is impleme

Strona 110

Glossary–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidelogical unit A physical or virtual devic

Strona 111 - Before Installing the Agent

Glossary–11metadata The data written to a disk for the purposes of controller administration. Metadata improves error detection and media defect manag

Strona 112

© 2001 Compaq Computer Corporation. Compaq, the Compaq logo, and StorageWorks Registered in U.S. Patent and Trademark Office.Microsoft, MS-DOS, Window

Strona 113 - Enter Subsystem Information

xx HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 1. General configuration flowchartConfigu

Strona 114

Glossary–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidenonredundant controller configuration(1)

Strona 115 - Final System Configuration

Glossary–13participating mode A mode within an L_Port that allows the port to participate in loop activities. A port must have a valid AL_PA to be in

Strona 116

Glossary–14 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guideprimary cabinet The primary cabinet is t

Strona 117

Glossary–15RAID level 5 A RAID storageset that, unlike RAID level 3, stores the parity information across all of the disk drives within the storageset

Strona 118

Glossary–16 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidereplacement policy The policy specified

Strona 119 - Reconfiguring the Agent

Glossary–17serial transmission A method transmission in which each bit of information is sent sequentially on a single channel rather than simultaneou

Strona 120 - −Can use the

Glossary–18 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidestripe The data divided into blocks and

Strona 121 - Removing the Agent

Glossary–19ULP process A function executing within a Fibre Channel node which conforms to the Upper Layer Protocol (ULP) requirements when interacting

Strona 122

Glossary–20 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidewrite-through cachingA cache management

Strona 123 - Configuration Procedures

IndexAaccessing the CLI, SWCC 1−23, 5−29accessing the configuration menuAgent 4−59, 4−62, 4−63ADD CONNECTIONSmultiple-bus failover 1−21transparent fai

Strona 124 - CXO7181A

About this Guide xxiFigure 2. Configuring storage with the CLICreate Storagesets and Partitions:Stripeset, Page 5-15Mirrorset, Page 5-15RAIDset, Page

Strona 125 - Cabling a Single Controller

Index–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidetoggling startup 4−59, 4−62, 4−70uninstallin

Strona 126 - Connections

Index–3comparison of container types 2−12completing configuration 3−39Configurationfabric topologyprocedure flowchartillustrated 1−ξξιϖconfigurationba

Strona 127 - Configure Controller Settings

Index–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideDddTru64 UNIX utility 3−73DECsafe 3−71deleti

Strona 128 - Restart the Controller

Index–5First enclosure of multiple-enclosure subsystemstorage map template 1 A−3, A−6, A−7, A−9,A−11, A−12, A−14format utilitylabeling LUNs 3−69functi

Strona 129

Index–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideLlabeling LUNsformat utility 3−69launchingCl

Strona 130 - For V5.1x Use

Index–7online helpSWCC B−8optionsfor mirrorsets 2−25for RAIDsets 2−24initialize 2−26other controller 1−3Ppager notification B−8configuring B−8partitio

Strona 131 - Setting Up a Controller Pair

Index–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guidestorage configuration 1−23restartingAgent 4−

Strona 132 - CXO6887B

Index–9RAIDsets 2−18striped mirrorsets 2−20stripesets 2−14profile 2−12example 2−13profiles A−1storageset profile 2−12storageset switchesSET command 2−

Strona 133

Index–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration UuninstallingAgent 4−73Client B−7unit numbersass

Strona 134

xxii HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 3. Configuring storage with SWCCGetting

Strona 135

About this Guide xxiiiBe sure to have the following information available before you call Compaq: Technical support registration number (if applicabl

Strona 137 - Configuring a Mirrorset

Chapter 1Planning a SubsystemThis chapter provides information that helps you plan how to configure the subsystem. Refer to Chapter 2 when planning th

Strona 138 - Configuring a RAIDset

1–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideDefining the SubsystemsThis section describes th

Strona 139

Planning a Subsystem 1–3Figure 1–2. Location of controllers and cache modules in a BA370 enclosureController Designations “This Controller” and “Othe

Strona 140 - Configuring a Partition

1–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 1–3. “This controller” and “other contro

Strona 141

Planning a Subsystem 1–5Selecting a Failover ModeFailover is a way to keep the storage array available to the host if one of the controllers becomes u

Strona 142 - Preferring Units

ContentsAbout this GuideText Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 143 - Configuration Options

1–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideUnits are divided between the host ports: Units

Strona 144 - Enabling Autospare

Planning a Subsystem 1–7Figure 1–6. Transparent failover—after failover from controller B to controller AMultiple-Bus Failover Mode Multiple-bus fail

Strona 145 - Deleting a Storageset

1–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideIn multiple-bus failover mode, you can specify w

Strona 146 - Changing Unit Switches

Planning a Subsystem 1–9Figure 1–7. Typical multiple-bus configurationSelecting a Cache ModeThe cache module supports read, read-ahead, write-through

Strona 147 - Chapter 6

1–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideRead Caching When the controller receives a rea

Strona 148

Planning a Subsystem 1–11Enabling Mirrored Caching In mirrored caching, half of each controller’s cache mirrors the companion controller’s cache, as s

Strona 149 - Chapter 7

1–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideThe CCL does the following: Allows the RAID Ar

Strona 150

Planning a Subsystem 1–13Enabling/Disabling CCL in SCSI-3 ModeThe CCL is enabled all the time. There is no option to enable/disable.ConnectionsThe ter

Strona 151 - Figure 7–2. Example system

1–14 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide If a controller pair is in transparent failov

Strona 152 - CLI Configuration Example

Planning a Subsystem 1–15Figure 1–10. Connections in single-link, transparent failover mode configurationsCXO7079BHostport 1activeHostport 2activeD10

Strona 153

iv HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideEnabling the CCL . . . . . . . . . . . . . . . .

Strona 154

1–16 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 1–11. Connections in multiple-bus failo

Strona 155

Planning a Subsystem 1–17 The UNIT_OFFSET switch in the ADD CONNECTIONS (or SET connections) commands The controller port to which the connection is

Strona 156

1–18 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 1–12. LUN presentation to hosts, as det

Strona 157

Planning a Subsystem 1–19Matching Units to Host Connections in Multiple-Bus Failover ModeIn multiple-bus failover mode, the ADD UNIT command creates a

Strona 158

1–20 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideAssigning Host Connection Offsets and Unit Numb

Strona 159 - Chapter 8

Planning a Subsystem 1–21Table 1–1 summarizes the recommendations for unit assignments based on the SCSI_VERSION switch.Selective Storage Presentation

Strona 160 - Cloning Data for Backup

1–22 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideRestricting Host Access by Separate LinksIn tra

Strona 161 - RUN CLONE

Planning a Subsystem 1–23Restricting Host Access by Disabling Access PathsIf more than one host is on a link (that is, attached to the same port), hos

Strona 162

1–24 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFor example:In Figure 1–13, assume both host co

Strona 163

Planning a Subsystem 1–25Figure 1–14. Limiting host access in multiple-bus failover modeCXO7078B Hostport 1activeHostport 2activeHostport 2activeHost

Strona 164 - Moving Storagesets

vChanging Characteristics through Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–23Enabling Switches . .

Strona 165

1–26 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFor example:Figure 1–14 shows a representative

Strona 166

Planning a Subsystem 1–27Restricting Host Access by OffsetsOffsets establish the start of the range of units that a host connection can access. Howeve

Strona 167 - Subsystem Profile Templates

1–28 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideWorldwide Names (Node IDs and Port IDs) A world

Strona 168 - Storageset Profile

Planning a Subsystem 1–29Figure 1–15 shows the placement of the worldwide name label for the Model 2200 enclosure, and Figure 1–16 for the BA370 enclo

Strona 169 - Enclosure

1–30 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideUnit Worldwide Names (LUN IDs)In addition, each

Strona 170 - BA370 Enclosure

Chapter 2Planning StorageThis chapter provides information to help you plan the storage configuration of your subsystem. Use the guidelines found in t

Strona 171

2–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideWhere to StartThe following procedure outlines t

Strona 172 - 4214R Disk Enclosure

Planning Storage 2–3Configuration RulesReview the following requirements and conditions to ensure that the storage configuration you are planning is a

Strona 173 - 4254 Disk Enclosure

2–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 2–1. PTL naming conventionThe controller

Strona 174

Planning Storage 2–5The Model 2200 controller enclosure can be combined with the following: Model 4214R disk enclosure — Ultra2 SCSI with 14 drive ba

Strona 175 - 4310R Disk Enclosure

vi HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideHSG80 Units and Tru64 UNIX Utilities. . . . . . .

Strona 176

2–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 2–3. PTL addressing in a single-bus conf

Strona 177 - 4350R Disk Enclosure

Planning Storage 2–7Figure 2–4. PTL addressing in a dual-bus configuration, three Model 4350R disk enclosuresModel 4350R Disk Enclosure Shelf 1 (dual

Strona 178 - 4314R Disk Enclosure

2–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 2–5. PTL addressing in a single-bus conf

Strona 179

Planning Storage 2–9Figure 2–6. PTL addressing in a dual-bus configuration, three Model 4354R disk enclosuresModel 4354R Disk Enclosure Shelf 1 (dual

Strona 180 - 4354R Disk Enclosure

2–10 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 2–7. Mapping a unit to physical disk dr

Strona 181 - Appendix B

Planning Storage 2–11Choosing a Container TypeDifferent applications may have different storage requirements. You probably want to configure more than

Strona 182 - Installing the Client

2–12 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideTable 2–1 compares the different kinds of conta

Strona 183 - During Installation

Planning Storage 2–13Storageset Name R1Disk Drives D10300, D20300, D10400, D20400Unit Number D101Partitions:RAIDset Switches:Mirrorset Switches:Initia

Strona 184

2–14 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStorageset Planning ConsiderationsThis section

Strona 185 - Host to the Navigation Tree

Planning Storage 2–15The relationship between the chunk size and the average request size determines if striping maximizes the request rate or the dat

Strona 186

viiConfigure Controller Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–5Restart the Controller

Strona 187

2–16 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide Striping does not protect against data loss.

Strona 188 - About the Online Help

Planning Storage 2–17Figure 2–12. Mirrorsets maintain two copies of the same dataFigure 2–13. Mirrorset example 2Keep these points in mind when plan

Strona 189 - Glossary

2–18 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide A mirrorset should only contain disk drives o

Strona 190

Planning Storage 2–19RAIDsets are similar to stripesets in that the I/O requests are broken into smaller “chunks” and striped across the disk drives.

Strona 191

2–20 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideStriped Mirrorset Planning ConsiderationsStripe

Strona 192

Planning Storage 2–21Figure 2–16. Striped mirrorset (example 2)Plan the mirrorset members, and plan the stripeset that will contain them. Review the

Strona 193

2–22 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuidePartition Planning ConsiderationsUse partitions

Strona 194

Planning Storage 2–23Guidelines for Partitioning Storagesets and Disk DrivesKeep these points in mind when planning partitions for storagesets and dis

Strona 195

2–24 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideIf you use CLI commands to configure the storag

Strona 196

Planning Storage 2–25Mirrorset SwitchesUse the following switches to control how a mirrorset behaves to ensure data availability: Replacement policy

Strona 197

viii HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideChanging RAIDset and Mirrorset Switches . . . .

Strona 198

2–26 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideChunk SizeSpecify the chunk size of the data to

Strona 199

Planning Storage 2–27Large chunk sizes also tend to increase the performance of random reads and writes. It is recommended that you use a chunk size o

Strona 200

2–28 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideSave ConfigurationThe SAVE CONFIGURATION switch

Strona 201

Planning Storage 2–29 CAPACITY—the number of logical blocks. The range is from 1 to the maximum container size. CYLINDERS—the number of cylinders us

Strona 202

2–30 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideExample Storage Map - Model 4310R Disk Enclosur

Strona 203

Planning Storage 2–31Figure 2–19. Model 4310R disk enclosure − example storage mapModel 4310R Disk Enclosure Shelf 4 (single-bus)Bay12345678910SCSI I

Strona 204

2–32 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideExample Storage Map - Model 4350R Disk Enclosur

Strona 205

Planning Storage 2–33Figure 2–20. Model 4350R disk enclosure − example storage mapExample Storage Map - Model 4314R Disk EnclosureFigure 2–21 shows a

Strona 206

2–34 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide Unit D101 is a 2-member striped mirrorset nam

Strona 207

Planning Storage 2–35Figure 2–21. Model 4314R disk enclosure − example storage mapModel 4314R Disk Enclosure Shelf 4 (single-bus)Bay 1234567891011121

Strona 208

ixAdding the Storage Subsystem and its Host to the Navigation Tree. . . . . . . . . . . . . . . . . . . . . . B–5Removing the Command Console Client

Strona 209

2–36 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideExample Storage Map - Model 4354R Disk Enclosur

Strona 210

Planning Storage 2–37Figure 2–22. Model 4354R disk enclosure − example storage mapModel 4354R Disk Enclosure Shelf 1 (dual-bus)SCSI Bus A SCSI Bus BB

Strona 211

2–38 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideUsing the LOCATE Command to Find DevicesIf you

Strona 212

Chapter 3Preparing the Host SystemThis chapter describes how to prepare your Tru64 UNIX host computer to accommodate the HSG80 controller storage subs

Strona 213

3–2 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideCAUTION: Controller and disk enclosures have no

Strona 214

Preparing the Host System 3–3Figure 3–1. Dual-Bus Enterprise Storage RAID Array Storage System1 SCSI Bus 1 Cable 2 SCSI Bus 2 Cable3 SCSI Bus 3 Cable

Strona 215

3–4 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuideFigure 3–2. Single-Bus Enterprise Storage RAID

Strona 216

Preparing the Host System 3–5Making a Physical ConnectionTo attach a host computer to the storage subsystem, install one or more host bus adapters int

Strona 217

3–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration GuidePreparing LUNs for Access by Tru64 UNIX FileSyst

Strona 218

Preparing the Host System 3–7For example, to create partitions on block device, dsk8, enter:# disklabel -rw dsk8 HSG80To view a LUN partition, enter:#

Komentarze do niniejszej Instrukcji

Brak uwag