5–40 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
03F80701 The EMU has detected one or more bad power supplies.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 07
03F90601 The EMU has detected one or more bad fans.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 06
03FA0D01 The EMU has detected an elevated temperature condition.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 0D
03FB0E01 The EMU has detected an external air sense fault.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 0E
03FC0F01 The EMU-detected power supply fault is now fixed.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 0F
03FD0F01 The EMU-detected bad-fan fault is now fixed. Note that in this instance, the
Associated Target, Associated Additional Sense Code, and Associated
Additional Sense Code Qualifier fields are undefined.
41 0F
03FE0F01 The EMU-detected elevated temperature fault is now fixed. Note that in this
instance, the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41 0F
03FF0F01 The EMU-detected external air sense fault is now fixed. Note that in this
instance, the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41 0F
07030B0A Failover Control detected a receive packet sequence number mismatch. The
controllers are out of synchronization with each other and are unable to
communicate. Note that in this instance, the Last Failure Code and Last
Failure Parameters fields are undefined.
05 0B
Table 5–15 Instance Codes (Sheet 19 of 24)
Instance
Code
Description Template
Repair
Action
Code