A-10 SMC Installation Guide
A.5 Cable the Terminal Server to the SMC System
Connect the management channel connector on the terminal server to
network adapter 2 on the SMC system.
Figure A–7 Terminal Server Management Channel Connector
1
PK-1769-00
1. Connect one end of the BN24Q–07 cable (17–04308–05) to the management
channel connector on the terminal server (
in Figure A–7).
2. Connect the other end of the cable to network adapter 2 on the SMC system
(Figure A–8). The network adapters are numbered from left to right on the
minitower; bottom to top on the desktop.
NOTE: BN24Q is a crossover cable that can be used only for a point-to-point
Ethernet connection. It cannot connect an Ethernet node to a hub. If
such a connection is required, use a BN25G cable (17–03212–xx).
Przeglądanie stron 191