Example command and response, using th e sample information in Step 3:
# /usr/bin/scu -f /dev/rscsi/c5t0d0 download /tmp/scu/msav686b397.bin
save segment
Downloading File “msa686b397.bin” of 1048576 bytes...
Download completed successfully...
DELAYING FOR 120 SECONDS WHILE FIRMWARE IS SAVED, PLEASE BE PATIENT...
120
CAUTION:
Do not restart the server or the MSA until the rmware download process is complete.
NOTE:
The MSA LCD panel displays the message FIRMWARE FLASH STARTED when the
download be gins and FIRMWARE FLASH DONE when the download is complete.
6. Wait for the CLI p
rompt to redisplay.
7. Wait for FIRMWARE FLASH DONE to display on the MSA LCD panel.
8. Power cycle the MSA.
NOTE:
In dual-controller congurations, rmware on the two controllers is compared each time
theMSAchassisisrestarted.Iftheversionsaremismatched,thesystempromptstoclone
the rmware on t
he controller with the latest version over to the controller with the earlier
version rmware. The following message is displayed on the LCD panel of the controller
with the earlier rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the rmware. Duringthecloningprocess,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
9. Verify that the controller rmware was updated by entering the SHOW INQUIRY comm a nd within the
SCU and reading the display.
Example command and response, using th e sample information in Step 3: