
HP ProLiant SL Advanced Power Manager User Guide Abstract This guide provides installation and operation guidance for the HP ProLiant SL Advanced Po
Introduction 10 The total rating of the Intelligent Extension Bar is 16 A. Callout Description 1 Row of green power indicators (one for each ou
Introduction 11 2U-chassis, DL2000 Scalable System Enclosure with four half-width 1U nodes Item Description 1 SL-APM 2 DL series enclosure 3 Bay
Introduction 12 Item Description 4 Bay 3 of a 2U-chassis, SL6000 Scalable System Enclosure with four 1U half-width nodes 4U-chassis, s6500 Scalabl
Introduction 13 4U-chassis, s6500 Scalable System Enclosure with two 4U half-width nodes Item Description 1 SL-APM 2 SL-APM Distribution Module 3
Introduction 14 4U-chassis, s6500 Scalable System Enclosure with four 2U half-width nodes Item Description 1 SL-APM 2 SL-APM Distribution Module
Installation and configuration 15 Installation and configuration Prerequisites for installation The SL-APM can be administered through the serial co
Installation and configuration 16 • Enter the commands manually. This procedure is for advanced users who want more control over the configuration
Installation and configuration 17 11. Save the new configuration. To save the new configuration, select Y. All settings relating to the SL-APM Ether
Installation and configuration 18 Verifying network communication To verify the network communication is working, enter PING <IP address>, whe
Command Line Interface 19 Command Line Interface Command line conventions CLI input is case insensitive except when otherwise noted. The CLI uses a
© Copyright 2009, 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr
Command Line Interface 20 2. When prompted, enter the assigned IP address or FQDN name of SL-APM. 3. Enter Administrator. 4. Enter a valid passwor
Command Line Interface 21 7 : Compute node (active) 8 : Compute node (active) Power s
Command Line Interface 22 1: enabled 2: enabled 3: enabled 4: enabled 5: enabled 6: enabled Input Feed
Command Line Interface 23 Serial #: USE119A2YW 2 : Compute node (active) Asset tag: myserver2 Serial #: USE
Command Line Interface 24 Amps Drawn : 0.830000 Infeed Status : On Infeed Load Status : Normal 4:
SL-APM logging 25 SL-APM logging Overview of logging Logging enables you to see the following information in SL-APM • Actions taken • Events • Ti
SL-APM logging 26 003:WED JAN 13 11:03:20 2010: Dist. Module 1, port 5, server 1 was powered off 004:WED JAN 13 11:03:29 2010: Dist. Modul
SL-APM logging 27 External logging To show the syslog server address configuration information, enter SHOW SYSLOG. To set the syslog server address
SL-APM logging 28 Fault logged message Description credentials Checksum failure - password credentials Checksum failure while reading account crede
Power capping 29 Power capping Power capping overview The HP ProLiant SL family of products provides a power capping feature that operates at the se
Contents 3 Contents Introduction ...
Power capping 30 SL-APM management requirements Minimum firmware requirements are: • SL-APM 1.40 • SL Power Management Controller (SL Chassis) enc
Power capping 31 Power capping licensing All servers that are being power capped must have the iLO\LO100 advanced license installed. Before a power
Power capping 32 committed to the SL-APM onboard EEPROM so that it becomes persistent when SL-APM is reset during operation. NOTE: The power ba
Power capping 33 Are you sure you wish to set a new power baseline for this system? (Y/N/Q) -> Yes Retrieving license information for chassis Pow
Power capping 34 In this example, APM Port (item 1) and DM Port (item 2) are illustrated. > show power baseline APMPort DMPort Serial Number Min
Power capping 35 1 3 6 259 n/a 344 (DC watts) 1 3 7 240 n/a 325 (DC watts) 1 3
Power capping 36 PDM port 1 PDM Port Load ---- ---- ---- 1 1 93 (AC watts) 1 2
Power capping 37 All values listed are in AC watts APMPort DMPort Serial Number Min Cap Max Cap Set Cap Slots Populated ------- ------ ----------
Power capping 38 7 (no Dist. Module present) 8 (no Dist. Module present) Total servers = 10 Total chassis = 2 Total fan wattage = 3
Power capping 39 Since SL-APM zones are merely definitions of user defined SL-APM group boundaries (and by extension any chassis that are plugged in
Contents 4 SL-APM and SL-APM Distribution Module cabling ... 31
Power capping 40 1 2 CNK71600K4 585 2372 1500 (8) 2 3 5 7 ------- ------- -------
Power capping 41 In the following figure, the SL-APM port 2 is connected to the SL-APM Distribution Module port 4. The distribution module port, in
Power capping 42 • A total count of all the servers and chassis listed • Total fan wattage for the listing • Total system wattage in DC watts •
Power capping 43 PDM Port Load ---- ---- ---- 1 (no PDM Extension present) 2 (no PDM Extension present) ---
Power capping 44 The poll cycle time varies depending on how many server chassis are plugged into the SL-APM system. The more chassis that are prese
General commands 45 General commands Working with passwords SL-APM has no factory-assigned password. You can set a password and enable or disable a
General commands 46 When entering a password in this manner, you must include quotation marks around the password being set. This form of command is
General commands 47 where: "<username>" is the account username. This command removes the specified account from the system. If the
General commands 48 The parameters enable the addition of all chassis on all SL-APM ports, all the chassis plugged into an SL-APM port through a SL-
General commands 49 Showing zones To display all the currently defined zones and their respective member chassis, enter SHOW ZONES. For example: mys
Contents 5 Troubleshooting ...
General commands 50 o To reset the password, enter SET PASSWORD. For more information, see "Setting SL-APM passwords (on page 45)". o To
General commands 51 SET NAME "alphabravo" Setting the time To set the time, enter SET TIME <month> <day> <year> <hou
General commands 52 • Serial Number • FRU File ID Showing the name To show the name, enter SHOW NAME. The name appears. As an example, the follow
General commands 53 Resetting factory settings To reset the factory settings, enter RESET FACTORY. All configuration and password settings will be l
Using SNMP 54 Using SNMP SNMP overview The architectural model for SNMP contains these components: • At least one network management station with m
Using SNMP 55 Setting the SNMP read-only community string To set the SNMP read-only community string, enter SET SNMP RO "<community_string&g
Using SNMP 56 • cpqRackPowerSupplyOK • cpqRackPowerSupplyRemoved • cpqRackPowerSupplyInserted • cpqRackServerBladeRemoved • cpqRackServerBladeI
Firmware 57 Firmware Upgrading the firmware You can perform firmware upgrades using either FTP or TFTP. To perform an upgrade: 1. Place the firmwar
Troubleshooting 58 Troubleshooting Alert messages The following messages appear in SL-APM. Message Where this issue occurs Required action There
Commands 59 Commands Clear faults • Command: CLEAR FAULTS • Description: Clears the fault log to have 0 entries. Clear log • Command: CLEAR LOG
Contents 6 Show time ...
Commands 60 Disable telnet • Command: DISABLE TELNET • Description: Turns off telnet access to the SL-APM board. Existing sessions will not be log
Commands 61 • Description: o Adds a new user to the system. A single SL-APM can maintain two login accounts, including the built-in Administrator
Commands 62 Exit • Command: EXIT • Description: Same as LOGOUT. Help • Command: HELP • Description: Displays a list of available commands. Log
Commands 63 Same as RESET. Reset factory WARNING: When you enter RESET FACTORY, SL-APM erases your entire configuration. Before resetting facto
Commands 64 Set name • Command: SET NAME "<name>" • Description: Assigns a name to SL-APM that will appear in the log and syslog e
Commands 65 ALL is used when the command applies to all nodes. You can also use it when the command applies to all the server nodes in a particular
Commands 66 • Description: o Sets the system time on the battery-backed clock. o All five parameters must be present. The hour parameter must be
Commands 67 percentage is then multiplied against each chassis maximum wattage value to arrive at an appropriate cap value for that individual chass
Commands 68 Show log • Command: SHOW LOG • Description: Shows the event log. Show syslog • Command: SHOW SYSLOG • Description: Shows the curren
Commands 69 SHOW RACK SHOW RACK <PORT#> SHOW RACK <PORT#> <DMPORT#> SHOW RACK ALL where: <PORT#> refers to the SL-APM port.
Introduction 7 Introduction SL-APM overview SL-APM is a single point of contact for HP ProLiant Scalable System administration. SL-APM enables: • D
Commands 70 Show asset info • Command: SHOW ASSETINFO SHOW ASSETINFO <PORT#> SHOW ASSETINFO <PORT#> <DMPORT#> where: <PORT#>
Commands 71 Show version • Command: SHOW VERSION SHOW VERSION ALL • Description: o Displays SL-APM firmware copyright, version, build date, and h
Commands 72 ADD ZONE my_zone 1 5 Adds the chassis plugged into SL-APM Distribution Module port 5 on SL-APM port 1 to zone MY_ZONE. If MY_ZONE did no
Commands 73 Removes one or more chassis from a zone definition. Enable pullpower • Command ENABLE POLLPOWER • Description Enables background proc
Commands 74 SET SNMP RO "<community_string>" • Description: Sets the SNMP read-only public string to the string specified as a para
Commands 75 — cpqRackEnclosureInserted — cpqRackEnclosureFanRemoved * — cpqRackEnclosureFanInserted * — cpqRackEnclosureFanFailed — cpqRackEncl
Supported MIB objects 76 Supported MIB objects Supported cpqRack MIB objects Object name Object identifier Notes Compaq 1.3.6.1.4.1.232 — cpqRac
Supported MIB objects 77 Object name Object identifier Notes cpqRackCommonEnclosureSerialNumPrev 1.3.6.1.4.1.232.22.2.3.1.1.1.24 — cpqRackCommonE
Supported MIB objects 78 Object name Object identifier Notes cpqRackServerBlade 1.3.6.1.4.1.232.22.2.4.1 — cpqRackSystemTime 1.3.6.1.4.1.232.22.2
Supported MIB objects 79 Object name Object identifier Notes exception of HP ProLiant s6500 Chassis cpqRackEnclosureFanInserted 1.3.6.1.4.1.232.22
Introduction 8 Item Description 7 PDM1 for HP Intelligent Modular PDU Extension Bar 8 PDM2 for HP Intelligent Modular PDU Extension Bar 9 SL-APM Di
Supported MIB objects 80 Object name Object identifier sysContact 1.3.6.1.2.1.1.4 sysName 1.3.6.1.2.1.1.5 sysLocation 1.3.6.1.2.1.1.6 sysServices 1
Supported MIB objects 81 Object name Object identifier ifNumber 1.3.6.1.2.1.2.1 ifNumber 1.3.6.1.2.1.2.1 ifTable 1.3.6.1.2.1.2.2 ifEntry 1.3.6.1.2.
Supported MIB objects 82 Object name Object identifier ipReasmFails 1.3.6.1.2.1.4.16 ipFragOKs 1.3.6.1.2.1.4.17 ipFragFails 1.3.6.1.2.1.4.18 ipFrag
Supported MIB objects 83 Object name Object identifier ipRoutingDiscards 1.3.6.1.2.1.4.23 ipInReceives 1.3.6.1.2.1.4.3 ipInHdrErrors 1.3.6.1.2.1.4.
Supported MIB objects 84 Object name Object identifier icmpInEchoReps 1.3.6.1.2.1.5.9 tcp 1.3.6.1.2.1.6 tcpRtoAlgorithm 1.3.6.1.2.1.6.1 tcpInSegs 1
Supported MIB objects 85 PDU identity table Two new tables are supported in the PDU section of the CPQ POWER MIB. These two tables are supported for
Support and other resources 86 Support and other resources Before you contact HP Be sure to have the following information available before you call
Acronyms and abbreviations 87 Acronyms and abbreviations DHCP Dynamic Host Configuration Protocol FQDN Fully Qualified Domain Name SL-APM HP ProLi
Documentation feedback 88 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat
Index 89 A accessing the CLI 20 ADD ACCOUNT 48, 64 ADD ZONE 40, 49, 75 alert messages 61 authorized reseller 89, 90 automatic discovery
Introduction 9 HP ProLiant SL Advanced Power Manager Distribution Module The distribution module includes a connector bay for the SL-APM and cables
Index 90 external logging 29 F factory settings, restoring 48 firmware, upgrading 60 first-time configuration 15 front panel components 7
Index 91 telephone numbers 89, 90 telnet session 21 topologies 21 troubleshooting 61 W website, HP 90 working with accounts 48 Z zone ov
Komentarze do niniejszej Instrukcji