Strona 1 - User Guide

HP ProLiant ML350 G6 Server User Guide Part Number 513503-002 March 2010 (Second Edition)

Strona 2 - Intended audience

Component identification 10 4To support options beyond 75W, install the 150W PCIe video/graphics controller power cable option (on page 82). Rear

Strona 3 - Contents

Configuration and utilities 100 HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other relate

Strona 4

Configuration and utilities 101 Remote support and analysis tools HP Insight Remote Support software HP Insight Remote Support software delivers sec

Strona 5

Configuration and utilities 102 IMPORTANT: Always perform a backup before installing or updating device drivers. ProLiant Support Packs PSPs re

Strona 6

Troubleshooting 103 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common

Strona 7 - Component identification

Troubleshooting 104 Symbols on equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditio

Strona 8 - Front panel LEDs and buttons

Troubleshooting 105 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug.

Strona 9 - Rear panel components

Troubleshooting 106 Prepare the server for diagnosis 1. Be sure the server is in the proper operating environment with adequate power, air conditio

Strona 10 - Rear panel LEDs and buttons

Troubleshooting 107 Service notifications To view the latest service notifications, refer to the HP website (http://www.hp.com/go/bizsupport). Selec

Strona 11 - System board components

Troubleshooting 108 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure

Strona 12 - Item Description

Troubleshooting 109 Item Refer to 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on t

Strona 13 - System board LEDs

Component identification 11 Item Description Status 7 NIC 2 activity LED Green or flashing = Network activity Off = No network activity 8 NIC 1

Strona 14 - System maintenance switch

Troubleshooting 110 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Strona 15 - SAS/SATA device numbers

Troubleshooting 111 • The external health LED is red or amber. • The internal health LED is red or amber. NOTE: For the location of server LED

Strona 17 - SAS and SATA hard drive LEDs

Troubleshooting 113 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system at

Strona 18 - Battery pack LEDs

Troubleshooting 114 Item Refer to OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system

Strona 19

Troubleshooting 115 • Server does not boot SmartStart Possible causes: • Corrupted operating system • Hard drive subsystem problem • Incorrect b

Strona 20 - FBWC module LEDs

Troubleshooting 116 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents (on p

Strona 21 - • Fan locations

Troubleshooting 117 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:

Strona 22

Troubleshooting 118 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in t

Strona 23

Battery replacement 119 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the ba

Strona 24

Component identification 12 Item Description 10 Front panel LED board connector 11 SAS connector B 12 SAS connector A 13 HP Smart Array P410i

Strona 25 - Operations

Regulatory compliance notices 120 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory complianc

Strona 26

Regulatory compliance notices 121 to radio communications. However, there is no guarantee that interference will not occur in a particular installat

Strona 27 - Remove the access panel

Regulatory compliance notices 122 Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Can

Strona 28 - Remove the media bay blank

Regulatory compliance notices 123 This symbol on the product or on its packaging indicates that this product must not be disposed of with your othe

Strona 29 - Remove the DIMM baffle

Regulatory compliance notices 124 Korean notice Class A equipment Class B equipment Chinese notice Class A equipment Laser compliance This prod

Strona 30 - Remove a fan blank

Regulatory compliance notices 125 WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline batte

Strona 31 - Optimum environment

Electrostatic discharge 126 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions y

Strona 32 - Temperature requirements

Server specifications 127 Server specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (

Strona 33 - Power requirements

Server specifications 128 Rated input current 10 A at 100 VAC 4.9 A at 200 VAC Rated input power 930 W at 100V AC input 1348 W at 200V AC input BT

Strona 34 - Rack warnings

Server specifications 129 Rated input frequency 50 Hz to 60 Hz Rated input current 5.5 A at 100 VAC 2.6 A at 200 VAC Rated input power 526 W at 1

Strona 35 - Setting up a tower server

Component identification 13 System board LEDs Item Description Status 1 Power supply 1 Amber = No AC power or failed power supply Off = Powe

Strona 36

Technical support 130 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical s

Strona 37

Technical support 131 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howe

Strona 38 - Registering the server

Technical support 132 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'information

Strona 39 - Processor option

Technical support 133 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das

Strona 40

Technical support 134 el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de comp

Strona 41

Technical support 135 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente

Strona 42

Technical support 136

Strona 43

Technical support 137

Strona 44 - Memory options

Acronyms and abbreviations 138 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADU Array Diagnostics Utility AMP Ad

Strona 45

Acronyms and abbreviations 139 NIC network interface controller NMI non-maskable interrupt ORCA Option ROM Configuration for Arrays PCI Express P

Strona 46 - Memory configurations

Component identification 14 Item Description Status 9 System fan 2 Amber = Fan is missing or has failed. Off = Fan is functioning. 10 Processor

Strona 47 - Low voltage DIMMs

Acronyms and abbreviations 140 TMRA recommended ambient operating temperature TPM trusted platform module UDIMM Unregistered Dual In-Line Memory M

Strona 48

Index 141 1 150W PCIe video/graphics controller power cable option 82 A access panel 27, 28 accessing servers 26 acoustics statement for Germa

Strona 49

Index 142 F fan assembly 65 fan bay numbering 20 fan blank 30 fan configurations 20 fans 20 FBWC module 20, 80 FCC rating label 120 fe

Strona 50

Index 143 ORCA (Option ROM Configuration for Arrays) 95 OS boot problems flowchart 114 P PATA optical drive 62 PCI Express conversion card 7

Strona 51 - Installing DIMMs

Index 144 Trusted Platform Module (TPM) 84, 85, 86 U UID LED 8, 10, 14, 25 updating the system ROM 98 USB support 99 utilities 91 utilitie

Strona 52

Component identification 15 Position Default Function S6 Off Off = No function On = Clear NVRAM S7 — Reserved S8 — Reserved S9 — Reserved

Strona 53 - Remove the hard drive blank

Component identification 16 • SFF configuration with a second SAS controller • LFF configuration

Strona 54 - Hard drive cage options

Component identification 17 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA

Strona 55

Component identification 18 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing irregularly Off The drive is active, and

Strona 56

Component identification 19 LED3 pattern LED4 pattern Interpretation — One blink every two seconds The system is powered down, and the cache

Strona 57

© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strona 58

Component identification 20 FBWC module LEDs The FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse sid

Strona 59

Component identification 21 • Fan locations Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4 Front fan 4 • Single-processor,

Strona 60

Component identification 22 Item Description 4 Processor 1 5 DIMM baffle • Single-processor, redundant fan configuration Item Description

Strona 61

Component identification 23 • Dual-processor, non-redundant fan configuration Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4

Strona 62 - Identifying guide screws

Component identification 24 Item Description 3 Front fan 3 4 Front fan 4 5 Processor 1 6 Processor 2 7 DIMM baffles 8 Large redundant fan air

Strona 63

Operations 25 Operations Power up the server To power up the server, press the Power On/Standby button. To determine status, see "Front panel L

Strona 64

Operations 26 3. After performing the installation or maintenance procedure, press the rail-release latches and slide the server back into the r

Strona 65

Operations 27 For operations involving removable media bay access, the media bay panel can be removed from the bezel. Remove the access panel

Strona 66

Operations 28 Install the access panel 1. Place the access panel on top of the server, allowing it to extend past the rear of the server approximat

Strona 67 - Power supply configuration

Operations 29 4. Remove the large redundant fan air baffle. Remove the DIMM baffle 1. Power down the server (on page 25). 2. Do one of the follo

Strona 68

Contents Component identification ... 7

Strona 69 - Expansion board options

Operations 30 Remove a fan blank 1. Power down the server (on page 25). 2. Do one of the following: o Open or remove the tower bezel, as needed (

Strona 70

Setup 31 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Strona 71 - PCI-X expansion cage option

Setup 32 In a tower configuration, leave at least a 7.6-cm (3-in) clearance space at the front and back of the server for proper ventilation. Rack s

Strona 72

Setup 33 CAUTION: To reduce the risk of damage to the equipment when installing third-party options: • Do not permit optional equipment to impede

Strona 73

Setup 34 Rack planning resources The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more inform

Strona 74

Setup 35 Contents of the rack server shipping carton Unpack the server shipping carton and locate the materials and documentation necessary for inst

Strona 75

Setup 36 2. Return the server to an upright position. 3. Connect peripheral devices to the server ("Rear panel components" on page 9).

Strona 76

Setup 37 2. Install an additional extender bracket (included with the server) to the cable management arm. Refer to "Converting the cable manag

Strona 77

Setup 38 • Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server. This process may require you to obtain a

Strona 78

Hardware options installation 39 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Strona 79

Hardware options installation ... 39 Introductio

Strona 80

Hardware options installation 40 6. Place the tower server on its side. 7. Open the processor retaining latch and the processor socket retaining br

Strona 81

Hardware options installation 41 10. Align the processor installation tool with the socket and install the processor. 11. Press down firmly until

Strona 82

Hardware options installation 42 12. Close the processor socket retaining bracket and the processor retaining latch. 13. Open the heatsink locking

Strona 83

Hardware options installation 43 14. Remove the heatsink protective cover. 15. Install the heatsink. 16. Close the heatsink locking levers. 17.

Strona 84

Hardware options installation 44 19. Install the fan into fan bay 3. 20. Connect the fan cable to the system board ("System board components&

Strona 85

Hardware options installation 45 IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the se

Strona 86

Hardware options installation 46 Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if curren

Strona 87

Hardware options installation 47 • Advanced ECC—provides the greatest memory capacity for a given DIMM size, while providing up to 4-bit error corr

Strona 88

Hardware options installation 48 Advanced ECC memory configuration Advanced ECC memory is the default memory protection mode for this server. Standa

Strona 89

Hardware options installation 49 • Each channel supports up to two Unbuffered DIMMs. • If quad-rank DIMMs are installed for a processor, a maximum

Strona 90

Redundant ROM support ... 98 USB sup

Strona 91 - Configuration and utilities

Hardware options installation 50 Single-processor Mirrored Memory population order For Mirrored Memory mode configurations with a single processor,

Strona 92 - HP ROM-Based Setup Utility

Hardware options installation 51 Single-processor Lockstep population order For Lockstep memory mode configurations with a single processor, populat

Strona 93 - Configuring mirrored memory

Hardware options installation 52 4. Remove the large redundant fan air baffle, if installed ("Remove the large redundant fan air baffle" o

Strona 94 - Array Configuration Utility

Hardware options installation 53 To install the component: 1. Remove the hard drive blank. 2. Open the release latch to prepare the drive for ins

Strona 95

Hardware options installation 54 3. Install the hard drive. 4. Determine the status of the drive by observing the drive LEDs ("SAS and SATA h

Strona 96 - Management tools

Hardware options installation 55 5. Remove all expansion boards. 6. Remove the large redundant fan air baffle, if installed ("Remove the larg

Strona 97 - HP Systems Insight Manager

Hardware options installation 56 10. Using the system board tray handles, slide the tray forward and remove the system board. 11. Connect the powe

Strona 98 - Redundant ROM support

Hardware options installation 57 Eight-bay SFF drive cage option Before installing the optional SFF hard drive cage, you must install an optional SA

Strona 99 - Diagnostic tools

Hardware options installation 58 6. Install the SFF hard drive cage into the server. 7. Connect the power cable to the optional hard drive backpla

Strona 100 - Array Diagnostic Utility

Hardware options installation 59 8. Connect the SAS cables to the optional SAS controller or optional SAS expander. 9. Install any hard drives or

Strona 101 - Keeping the system current

Battery replacement notice ...

Strona 102 - Care Pack

Hardware options installation 60 4. Extend the primary hard drive cage from the chassis. 5. Disconnect the existing SAS cable from the SAS connect

Strona 103 - Troubleshooting

Hardware options installation 61 o The "2LFF" labeled connector to the optional hard drive cage 7. Thread the LED and SAS/SATA controlle

Strona 104 - Warnings and cautions

Hardware options installation 62 o The "6LFF" labeled connector to the primary hard drive cage 10. Connect the remaining connector to SA

Strona 105 - Symptom information

Hardware options installation 63 To install a half-height or full-height media device: 1. Power down the server (on page 25). 2. Do one of the fol

Strona 106 - Loose connections

Hardware options installation 64 8. Slide the drive into the bay until it clicks. 9. When shipping a server with a full-height device installed, re

Strona 107 - Troubleshooting flowcharts

Hardware options installation 65 4. Install the silver shipping screw into the full-height device. Redundant fan assembly option To install the co

Strona 108 - General diagnosis flowchart

Hardware options installation 66 7. Align the baffle guide posts with the holes on the fan and the system board. 8. Install the large air baffle.

Strona 109

Hardware options installation 67 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord ground

Strona 110 - Symptoms:

Hardware options installation 68 CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded (

Strona 111

Hardware options installation 69 6. Connect the power cord to the AC power source. 7. Be sure that the power supply LED is illuminated green ("

Strona 112 - Troubleshooting 112

Component identification 7 Component identification Front panel components Item Description 1 Power On/Standby button 2 UID button 3 USB con

Strona 113 - POST problems flowchart

Hardware options installation 70 5. Remove the expansion slot cover. CAUTION: To prevent improper cooling and thermal damage, do not operate th

Strona 114 - OS boot problems flowchart

Hardware options installation 71 5. Install the expansion board. 6. Close the expansion slot latch to secure the board. 7. Connect any required i

Strona 115

Hardware options installation 72 4. Remove the two T-10 screws from the rear panel, and then remove the rear access panel. Retain the screws for sec

Strona 116

Hardware options installation 73 6. Remove the four T-15 screws from the hard drive cage, and then partially extend the hard drive cage from the cha

Strona 117 - • Redundancy failure

Hardware options installation 74 8. Remove a PCI-X expansion slot cover. 9. Install PCI-X expansion boards in the PCI-X expansion cage.

Strona 118 - Troubleshooting 118

Hardware options installation 75 10. Install the PCI-X expansion cage. Secure the assembly with the screws from the rear access panel. 11. Turn th

Strona 119 - Battery replacement

Hardware options installation 76 With the PCI-X expansion cage option, the additional PCI-X slots are recognized as slot 1 by the ROM. 15. Close t

Strona 120 - Class B equipment

Hardware options installation 77 b. Connect the extension to the first power connector of both system power cables. 19. Connect the power connecto

Strona 121 - Modifications

Hardware options installation 78 o Install the server in the rack. 24. Connect any external cables to the PCI-X expansion boards. 25. Power up the

Strona 122 - • EMC Directive 2004/108/EC

Hardware options installation 79 6. Install the cache module. 7. Connect the cable to the cache module. 8. Connect the cable to the battery pack

Strona 123 - BSMI notice

Component identification 8 Front panel LEDs and buttons Item Description Status 1 System power LED Green = Power on Flashing green = Waiting

Strona 124 - Battery replacement notice

Hardware options installation 80 10. Install the access panel (on page 28). 11. Do one of the following: o Close or install the tower bezel, a

Strona 125 - (Geräuschemission)

Hardware options installation 81 7. Install the FBWC module. 8. Connect the cable. 9. Install the capacitor pack. 10. Install the large redund

Strona 126 - Electrostatic discharge

Hardware options installation 82 11. Install the access panel. 12. Do one of the following: o Close or install the tower bezel, as needed. o Slid

Strona 127 - Server specifications

Hardware options installation 83 7. Remove the DIMM baffles ("Remove the DIMM baffle" on page 29). 8. Remove all fans. 9. Loosen the tw

Strona 128

Hardware options installation 84 11. Connect the 10-pin connector on the PCIe power cable to the power supply backplane. Be sure to thread the cable

Strona 129

Hardware options installation 85 • Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board. • When in

Strona 130 - Technical support

Hardware options installation 86 5. Install the TPM board. Press down on the connector to seat the board ("System board components" on pag

Strona 131 - Technical support 131

Hardware options installation 87 To help ensure maximum security, observe the following guidelines when retaining the recovery key/password: • Alwa

Strona 132 - Customer Self Repair

Hardware options installation 88 2. Disconnect all rear panel cabling ("Rear panel components" on page 9). 3. Remove the tower bezel (&qu

Strona 133 - Technical support 133

Hardware options installation 89 c. Slide them back and away from the chassis.

Strona 134 - Reparo feito pelo cliente

Component identification 9 Rear panel components Item Description 1 Power supply bay 2 2 Keyboard connector 3 Power supply bay 1 (populat

Strona 135 - Technical support 135

Hardware options installation 90 6. Install the foot blanks. 7. Remove the access panel (on page 27). 8. Align the pins on the rack bezel with th

Strona 136 - Technical support 136

Configuration and utilities 91 Configuration and utilities Configuration tools SmartStart software SmartStart is a collection of software that optim

Strona 137 - Technical support 137

Configuration and utilities 92 variables to determine the configuration and then writes the results to an editable script file. This file can then b

Strona 138 - Acronyms and abbreviations

Configuration and utilities 93 NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the

Strona 139

Configuration and utilities 94 7. Press the Esc key to exit the current menu or press the F10 key to exit RBSU. For more information on mirrored mem

Strona 140

Configuration and utilities 95 • Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab (formerly known as

Strona 141 - Index 141

Configuration and utilities 96 WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NO

Strona 142 - Index 142

Configuration and utilities 97 Integrated Lights-Out 2 technology The iLO 2 subsystem is a standard component of selected ProLiant servers that prov

Strona 143 - Index 143

Configuration and utilities 98 IMPORTANT: You must install and use HP SIM to benefit from the Pre-Failure Warranty for processors, SAS and SATA ha

Strona 144 - Index 144

Configuration and utilities 99 USB support and functionality USB support HP provides both standard USB support and legacy USB support. Standard supp