HP ProLiant ML350 G6 Server User Guide Part Number 513503-002 March 2010 (Second Edition)
Component identification 10 4To support options beyond 75W, install the 150W PCIe video/graphics controller power cable option (on page 82). Rear
Configuration and utilities 100 HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other relate
Configuration and utilities 101 Remote support and analysis tools HP Insight Remote Support software HP Insight Remote Support software delivers sec
Configuration and utilities 102 IMPORTANT: Always perform a backup before installing or updating device drivers. ProLiant Support Packs PSPs re
Troubleshooting 103 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common
Troubleshooting 104 Symbols on equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditio
Troubleshooting 105 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug.
Troubleshooting 106 Prepare the server for diagnosis 1. Be sure the server is in the proper operating environment with adequate power, air conditio
Troubleshooting 107 Service notifications To view the latest service notifications, refer to the HP website (http://www.hp.com/go/bizsupport). Selec
Troubleshooting 108 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure
Troubleshooting 109 Item Refer to 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on t
Component identification 11 Item Description Status 7 NIC 2 activity LED Green or flashing = Network activity Off = No network activity 8 NIC 1
Troubleshooting 110 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.
Troubleshooting 111 • The external health LED is red or amber. • The internal health LED is red or amber. NOTE: For the location of server LED
Troubleshooting 112
Troubleshooting 113 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system at
Troubleshooting 114 Item Refer to OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system
Troubleshooting 115 • Server does not boot SmartStart Possible causes: • Corrupted operating system • Hard drive subsystem problem • Incorrect b
Troubleshooting 116 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents (on p
Troubleshooting 117 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:
Troubleshooting 118 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in t
Battery replacement 119 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the ba
Component identification 12 Item Description 10 Front panel LED board connector 11 SAS connector B 12 SAS connector A 13 HP Smart Array P410i
Regulatory compliance notices 120 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory complianc
Regulatory compliance notices 121 to radio communications. However, there is no guarantee that interference will not occur in a particular installat
Regulatory compliance notices 122 Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Can
Regulatory compliance notices 123 This symbol on the product or on its packaging indicates that this product must not be disposed of with your othe
Regulatory compliance notices 124 Korean notice Class A equipment Class B equipment Chinese notice Class A equipment Laser compliance This prod
Regulatory compliance notices 125 WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline batte
Electrostatic discharge 126 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions y
Server specifications 127 Server specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (
Server specifications 128 Rated input current 10 A at 100 VAC 4.9 A at 200 VAC Rated input power 930 W at 100V AC input 1348 W at 200V AC input BT
Server specifications 129 Rated input frequency 50 Hz to 60 Hz Rated input current 5.5 A at 100 VAC 2.6 A at 200 VAC Rated input power 526 W at 1
Component identification 13 System board LEDs Item Description Status 1 Power supply 1 Amber = No AC power or failed power supply Off = Powe
Technical support 130 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical s
Technical support 131 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howe
Technical support 132 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'information
Technical support 133 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das
Technical support 134 el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de comp
Technical support 135 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente
Technical support 136
Technical support 137
Acronyms and abbreviations 138 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADU Array Diagnostics Utility AMP Ad
Acronyms and abbreviations 139 NIC network interface controller NMI non-maskable interrupt ORCA Option ROM Configuration for Arrays PCI Express P
Component identification 14 Item Description Status 9 System fan 2 Amber = Fan is missing or has failed. Off = Fan is functioning. 10 Processor
Acronyms and abbreviations 140 TMRA recommended ambient operating temperature TPM trusted platform module UDIMM Unregistered Dual In-Line Memory M
Index 141 1 150W PCIe video/graphics controller power cable option 82 A access panel 27, 28 accessing servers 26 acoustics statement for Germa
Index 142 F fan assembly 65 fan bay numbering 20 fan blank 30 fan configurations 20 fans 20 FBWC module 20, 80 FCC rating label 120 fe
Index 143 ORCA (Option ROM Configuration for Arrays) 95 OS boot problems flowchart 114 P PATA optical drive 62 PCI Express conversion card 7
Index 144 Trusted Platform Module (TPM) 84, 85, 86 U UID LED 8, 10, 14, 25 updating the system ROM 98 USB support 99 utilities 91 utilitie
Component identification 15 Position Default Function S6 Off Off = No function On = Clear NVRAM S7 — Reserved S8 — Reserved S9 — Reserved
Component identification 16 • SFF configuration with a second SAS controller • LFF configuration
Component identification 17 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA
Component identification 18 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing irregularly Off The drive is active, and
Component identification 19 LED3 pattern LED4 pattern Interpretation — One blink every two seconds The system is powered down, and the cache
© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr
Component identification 20 FBWC module LEDs The FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse sid
Component identification 21 • Fan locations Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4 Front fan 4 • Single-processor,
Component identification 22 Item Description 4 Processor 1 5 DIMM baffle • Single-processor, redundant fan configuration Item Description
Component identification 23 • Dual-processor, non-redundant fan configuration Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4
Component identification 24 Item Description 3 Front fan 3 4 Front fan 4 5 Processor 1 6 Processor 2 7 DIMM baffles 8 Large redundant fan air
Operations 25 Operations Power up the server To power up the server, press the Power On/Standby button. To determine status, see "Front panel L
Operations 26 3. After performing the installation or maintenance procedure, press the rail-release latches and slide the server back into the r
Operations 27 For operations involving removable media bay access, the media bay panel can be removed from the bezel. Remove the access panel
Operations 28 Install the access panel 1. Place the access panel on top of the server, allowing it to extend past the rear of the server approximat
Operations 29 4. Remove the large redundant fan air baffle. Remove the DIMM baffle 1. Power down the server (on page 25). 2. Do one of the follo
Contents Component identification ... 7
Operations 30 Remove a fan blank 1. Power down the server (on page 25). 2. Do one of the following: o Open or remove the tower bezel, as needed (
Setup 31 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and
Setup 32 In a tower configuration, leave at least a 7.6-cm (3-in) clearance space at the front and back of the server for proper ventilation. Rack s
Setup 33 CAUTION: To reduce the risk of damage to the equipment when installing third-party options: • Do not permit optional equipment to impede
Setup 34 Rack planning resources The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more inform
Setup 35 Contents of the rack server shipping carton Unpack the server shipping carton and locate the materials and documentation necessary for inst
Setup 36 2. Return the server to an upright position. 3. Connect peripheral devices to the server ("Rear panel components" on page 9).
Setup 37 2. Install an additional extender bracket (included with the server) to the cable management arm. Refer to "Converting the cable manag
Setup 38 • Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server. This process may require you to obtain a
Hardware options installation 39 Hardware options installation Introduction If more than one option is being installed, read the installation instru
Hardware options installation ... 39 Introductio
Hardware options installation 40 6. Place the tower server on its side. 7. Open the processor retaining latch and the processor socket retaining br
Hardware options installation 41 10. Align the processor installation tool with the socket and install the processor. 11. Press down firmly until
Hardware options installation 42 12. Close the processor socket retaining bracket and the processor retaining latch. 13. Open the heatsink locking
Hardware options installation 43 14. Remove the heatsink protective cover. 15. Install the heatsink. 16. Close the heatsink locking levers. 17.
Hardware options installation 44 19. Install the fan into fan bay 3. 20. Connect the fan cable to the system board ("System board components&
Hardware options installation 45 IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the se
Hardware options installation 46 Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if curren
Hardware options installation 47 • Advanced ECC—provides the greatest memory capacity for a given DIMM size, while providing up to 4-bit error corr
Hardware options installation 48 Advanced ECC memory configuration Advanced ECC memory is the default memory protection mode for this server. Standa
Hardware options installation 49 • Each channel supports up to two Unbuffered DIMMs. • If quad-rank DIMMs are installed for a processor, a maximum
Redundant ROM support ... 98 USB sup
Hardware options installation 50 Single-processor Mirrored Memory population order For Mirrored Memory mode configurations with a single processor,
Hardware options installation 51 Single-processor Lockstep population order For Lockstep memory mode configurations with a single processor, populat
Hardware options installation 52 4. Remove the large redundant fan air baffle, if installed ("Remove the large redundant fan air baffle" o
Hardware options installation 53 To install the component: 1. Remove the hard drive blank. 2. Open the release latch to prepare the drive for ins
Hardware options installation 54 3. Install the hard drive. 4. Determine the status of the drive by observing the drive LEDs ("SAS and SATA h
Hardware options installation 55 5. Remove all expansion boards. 6. Remove the large redundant fan air baffle, if installed ("Remove the larg
Hardware options installation 56 10. Using the system board tray handles, slide the tray forward and remove the system board. 11. Connect the powe
Hardware options installation 57 Eight-bay SFF drive cage option Before installing the optional SFF hard drive cage, you must install an optional SA
Hardware options installation 58 6. Install the SFF hard drive cage into the server. 7. Connect the power cable to the optional hard drive backpla
Hardware options installation 59 8. Connect the SAS cables to the optional SAS controller or optional SAS expander. 9. Install any hard drives or
Battery replacement notice ...
Hardware options installation 60 4. Extend the primary hard drive cage from the chassis. 5. Disconnect the existing SAS cable from the SAS connect
Hardware options installation 61 o The "2LFF" labeled connector to the optional hard drive cage 7. Thread the LED and SAS/SATA controlle
Hardware options installation 62 o The "6LFF" labeled connector to the primary hard drive cage 10. Connect the remaining connector to SA
Hardware options installation 63 To install a half-height or full-height media device: 1. Power down the server (on page 25). 2. Do one of the fol
Hardware options installation 64 8. Slide the drive into the bay until it clicks. 9. When shipping a server with a full-height device installed, re
Hardware options installation 65 4. Install the silver shipping screw into the full-height device. Redundant fan assembly option To install the co
Hardware options installation 66 7. Align the baffle guide posts with the holes on the fan and the system board. 8. Install the large air baffle.
Hardware options installation 67 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord ground
Hardware options installation 68 CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded (
Hardware options installation 69 6. Connect the power cord to the AC power source. 7. Be sure that the power supply LED is illuminated green ("
Component identification 7 Component identification Front panel components Item Description 1 Power On/Standby button 2 UID button 3 USB con
Hardware options installation 70 5. Remove the expansion slot cover. CAUTION: To prevent improper cooling and thermal damage, do not operate th
Hardware options installation 71 5. Install the expansion board. 6. Close the expansion slot latch to secure the board. 7. Connect any required i
Hardware options installation 72 4. Remove the two T-10 screws from the rear panel, and then remove the rear access panel. Retain the screws for sec
Hardware options installation 73 6. Remove the four T-15 screws from the hard drive cage, and then partially extend the hard drive cage from the cha
Hardware options installation 74 8. Remove a PCI-X expansion slot cover. 9. Install PCI-X expansion boards in the PCI-X expansion cage.
Hardware options installation 75 10. Install the PCI-X expansion cage. Secure the assembly with the screws from the rear access panel. 11. Turn th
Hardware options installation 76 With the PCI-X expansion cage option, the additional PCI-X slots are recognized as slot 1 by the ROM. 15. Close t
Hardware options installation 77 b. Connect the extension to the first power connector of both system power cables. 19. Connect the power connecto
Hardware options installation 78 o Install the server in the rack. 24. Connect any external cables to the PCI-X expansion boards. 25. Power up the
Hardware options installation 79 6. Install the cache module. 7. Connect the cable to the cache module. 8. Connect the cable to the battery pack
Component identification 8 Front panel LEDs and buttons Item Description Status 1 System power LED Green = Power on Flashing green = Waiting
Hardware options installation 80 10. Install the access panel (on page 28). 11. Do one of the following: o Close or install the tower bezel, a
Hardware options installation 81 7. Install the FBWC module. 8. Connect the cable. 9. Install the capacitor pack. 10. Install the large redund
Hardware options installation 82 11. Install the access panel. 12. Do one of the following: o Close or install the tower bezel, as needed. o Slid
Hardware options installation 83 7. Remove the DIMM baffles ("Remove the DIMM baffle" on page 29). 8. Remove all fans. 9. Loosen the tw
Hardware options installation 84 11. Connect the 10-pin connector on the PCIe power cable to the power supply backplane. Be sure to thread the cable
Hardware options installation 85 • Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board. • When in
Hardware options installation 86 5. Install the TPM board. Press down on the connector to seat the board ("System board components" on pag
Hardware options installation 87 To help ensure maximum security, observe the following guidelines when retaining the recovery key/password: • Alwa
Hardware options installation 88 2. Disconnect all rear panel cabling ("Rear panel components" on page 9). 3. Remove the tower bezel (&qu
Hardware options installation 89 c. Slide them back and away from the chassis.
Component identification 9 Rear panel components Item Description 1 Power supply bay 2 2 Keyboard connector 3 Power supply bay 1 (populat
Hardware options installation 90 6. Install the foot blanks. 7. Remove the access panel (on page 27). 8. Align the pins on the rack bezel with th
Configuration and utilities 91 Configuration and utilities Configuration tools SmartStart software SmartStart is a collection of software that optim
Configuration and utilities 92 variables to determine the configuration and then writes the results to an editable script file. This file can then b
Configuration and utilities 93 NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the
Configuration and utilities 94 7. Press the Esc key to exit the current menu or press the F10 key to exit RBSU. For more information on mirrored mem
Configuration and utilities 95 • Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab (formerly known as
Configuration and utilities 96 WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NO
Configuration and utilities 97 Integrated Lights-Out 2 technology The iLO 2 subsystem is a standard component of selected ProLiant servers that prov
Configuration and utilities 98 IMPORTANT: You must install and use HP SIM to benefit from the Pre-Failure Warranty for processors, SAS and SATA ha
Configuration and utilities 99 USB support and functionality USB support HP provides both standard USB support and legacy USB support. Standard supp