HP CONFIDENTIAL Writer: Woody Jernigan File Name: a-frnt Codename: Sopwith Part Number: 252621-003 Last Saved On: 9/17/03 12:49 PM HP ProLiant DL380
1 Packaged Cluster Components The HP ProLiant DL380 Generation 3 (G3) Packaged Cluster consists of two ProLiant DL380 G3 servers and an HP StorageWor
Packaged Cluster Components Configuration Fixture The packaged cluster ships in a two-piece configuration fixture (1) that can be used to configure th
Packaged Cluster Components Configuration Fixture Disposal The server fixture and the storage fixture are environmentally safe and recyclable. The con
Packaged Cluster Components 1-4 HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Jernigan
2 Setup Preparations Required Materials Before setting up your packaged cluster, locate the following materials included in the shipping box: • • • •
Setup Preparations 2-2 HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Jernigan File Nam
3 Component and LED Identification ProLiant DL380 Generation 3 Server Table 3-1: Front Panel Components Item Description 1 Hard drive bays 2 Ba
Component and LED Identification 4 CD-ROM drive Table 3-2: Front Panel LEDs and Buttons Item Description Status 1 Internal health LED Green = Norm
Component and LED Identification Table 3-2: Front Panel LEDs and Buttons continued Item Description Status 5 UID LED button Blue = Activated Flash
Component and LED Identification Table 3-3: Rear Panel Components Item Description Connector Color 1 Hot-plug PCI-X expansion slot 3 (bus 6) 64-b
HP CONFIDENTIAL Writer: Woody Jernigan File Name: a-frnt Codename: Sopwith Part Number: 252621-003 Last Saved On: 9/17/03 12:49 PM © 2003 Hewlett-
Component and LED Identification Table 3-4: Rear Panel LEDs and Buttons Item Description LED Color Status 1 PCI Hot Plug fault LED (slot 3) Amber
Component and LED Identification Table 3-4: Rear Panel LEDs and Buttons continued Item Description LED Color Status 6 RJ-45 activity LED Green On
Component and LED Identification MSA500 System Table 3-5: Front Panel Components Item Description 1 Bezel blank (bay for optional redundant contr
Component and LED Identification Table 3-6: Enclosure LEDs Item LED Description Status 1 Shared Storage Module Flashing green = Module is operatin
Component and LED Identification Table 3-7: Rear Panel Components Item Description 1 Interconnect blanks (required for proper airflow) 2 Power su
Component and LED Identification 3-10 HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Je
4 Setup in the Configuration Fixture Perform the following procedures to set up the packaged cluster in the configuration fixture. This setup procedu
Setup in the Configuration Fixture Installing Hardware Options NOTE: Detailed option installation instructions are available with the options and a
Setup in the Configuration Fixture Cabling the System in the Configuration Fixture NOTE: The server fixture should be placed on top of the storage f
Setup in the Configuration Fixture 3. Connect the peripheral devices, such as the keyboard, mouse, and monitor. For information on peripheral device
HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide iii HP CONFIDENTIAL Writer: Woody Jernigan File Name: a-frnt Codename
Setup in the Configuration Fixture Powering On and Configuring the Packaged Cluster 1. Power on the storage system and wait for the controllers to in
Setup in the Configuration Fixture 4-6 HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody J
5 Setup and Installation in a Rack Perform the following procedures to set up the packaged cluster in a rack. WARNING: To reduce the risk of pers
Setup and Installation in a Rack Rack Planning Resources The rack resource kit ships with all HP branded or Compaq branded 9000-, 10,000-, and H9-seri
Setup and Installation in a Rack 1. Locate the following materials necessary for installing the storage system. Table 5-1: Rack-Mounting Hardware
Setup and Installation in a Rack 2. Use the instructions provided on the rack template to mark the rack for rail locations. WARNING: The storage s
Setup and Installation in a Rack 3. Insert the front end of the left rack rail into the inside front of the rack. Be sure that the pins extend throug
Setup and Installation in a Rack 4. Slide the back end of the left rack rail into the inside rear of the rack. Be sure that the pins extend through t
Setup and Installation in a Rack 6. Remove the hook-and-loop fasteners (1) securing the VHDCI SCSI cables and the Ethernet crossover cable to the sto
Setup and Installation in a Rack 8. Loosen the thumbscrews that secure the storage system and slide the storage system from the storage system fixtur
Contents iv HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Jernigan File Name: a-frnt C
Setup and Installation in a Rack 9. Align the storage system with the rails and slide it into the rack. WARNING: The storage system weight, as ass
Setup and Installation in a Rack 10. Secure the storage system to the rack. IMPORTANT: Tightening of the shipping bracket is only necessary if the
Setup and Installation in a Rack 11. Use the shipping bracket to secure the system in the rack for shipping: a. Loosen the thumbscrew on the shippin
Setup and Installation in a Rack 1. Locate the following materials necessary for installing the servers. Table 5-2: Rack-Mounting Hardware and Tem
Setup and Installation in a Rack 2. Mark the rack. CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the ra
Setup and Installation in a Rack 4. Secure each server rail to the server. 5. Secure the left and right standard rack rails to the appropriate side
Setup and Installation in a Rack 6. Extend the slides from the standard rack rails, and then slide the server rails into the slides. WARNING: To r
Setup and Installation in a Rack 7. Press the rail-release latches and slide the server into the rack. WARNING: To reduce the risk of personal inj
Setup and Installation in a Rack Installing Hardware Options IMPORTANT: If your system was previously configured, skip to “Cabling the System in a R
Setup and Installation in a Rack 2. Secure the cable management bracket to the rail. 3. Connect the VHDCI SCSI cables labeled A and B from the stor
HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide v HP CONFIDENTIAL Writer: Woody Jernigan File Name: a-frnt Codename:
Setup and Installation in a Rack 4. If you are configuring a Microsoft® or Linux operating system, connect the Ethernet crossover cable between the s
Setup and Installation in a Rack 7. Route the cables and secure to the cable management arm. 8. Connect the power cords to the AC power source.
Setup and Installation in a Rack Powering On and Configuring the Packaged Cluster 1. Power on the storage system and wait for the controllers to init
Setup and Installation in a Rack 5-22 HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Je
Index A K Array Configuration Utility 4-5, 5-21 KVM switchbox 4-4, 5-19 authorized reseller ix M C M-Series rack 5-2 cable Ethernet crosso
Index R rack M-Series 5-2 populating 5-13 third-party 5-2 rack-mounting hardware servers 5-12 storage system 5-3 RAID 4-5, 5-21 RBSU (ROM-
About This Guide vi HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Jernigan File Name:
About This Guide HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide vii HP CONFIDENTIAL Writer: Woody Jernigan File Name:
About This Guide viii HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide HP CONFIDENTIAL Writer: Woody Jernigan File Name
About This Guide HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide ix HP CONFIDENTIAL Writer: Woody Jernigan File Name: